Electrical · PDF, DWG or DXF in · DWG out

AI electrical layout: outlets, lighting and panels on a floor plan

Type what the plan needs and Aginera drafts it: receptacles, lights, switches, panelboards and home runs, placed room by room as real CAD blocks on AIA/NCS electrical layers. Upload a PDF, DWG or DXF and download the edited sheet as DWG or DXF.

Part of the Aginera AI MEP drafter.

What to type

Write the change the way you would say it to a drafter. Name the rooms as they are written on the drawing. Each request builds on the last.

  • “Add 4 duplex receptacles and a ceiling light with a switch in each bedroom”
  • “Put a GFCI receptacle in each toilet”
  • “Add panelboard LP-1 in the lobby and a home run from each bedroom”
  • “Add 2x4 troffers and an occupancy sensor in every office”

Electrical symbols and layers

Symbols, placed as blocks

  • • Duplex, GFCI, quad and floor receptacles
  • • Switches: single-pole, three-way and dimmer
  • • Occupancy sensors
  • • Ceiling, recessed, 2x4 troffer, wall and emergency lights
  • • Exit signs
  • • Panelboards
  • • Junction boxes
  • • Disconnects and motor connections

Runs, drawn at right angles

  • • Home runs
  • • Conduit
  • • Cable tray
  • • Lighting circuits

Also on request: tags and numbering, notes, a bill of materials table and a symbol legend drawn on the sheet.

Symbol groupNCS layer
ReceptaclesE-POWR-DEVC
Light fixturesE-LITE-FIXT
SwitchesE-LITE-SWCH
PanelboardsE-POWR-PANL

Layers follow the AIA/NCS (US National CAD Standard) naming. The bill of materials drawn on the sheet names the layer of each item.

What the result looks like

Residential first-floor plan converted from PDF to CAD, with receptacles, ceiling lights, switches, exhaust fans, a smoke detector and panelboard LP-1 drawn in red by typed request, and a bill of materials table listing each item with its NCS layer and quantity
A real first-floor plan after a few typed requests. The new work is in red: 8 duplex receptacles, 2 GFCI receptacles, 4 ceiling lights, 2 switches, 2 exhaust fans, 1 smoke detector and panelboard LP-1. The bill of materials on the right was drawn on the sheet and names the layer of each item.

What it does not do

Aginera drafts the change. A licensed professional must check the result before anything is built.

It does no load, voltage-drop or code calculations, so it does not size circuits or panels. Say how many devices you want in each room.

No calculations

It does no load, voltage-drop, hydraulic or code calculations. It places and draws what you ask for.

No dimensions, hatching, revision clouds or title-block edits

Add those in your CAD program after you download the DWG.

No Revit and no 3D

It works on 2D PDF, DWG and DXF drawings. It does not open or write Revit (RVT) files.

First drawing sheet of a multi-sheet PDF

On a PDF with several sheets it edits the first drawing sheet.

Rooms need a name on the drawing

Rooms are found from the room names written on the sheet. A room that is open to the next space, or has no name, may need the request re-worded.

Runs are not clash-checked

Duct, pipe and conduit runs are routed at right angles. They are not checked against structure or other services.

What it costs

Questions people ask

Can AI add electrical outlets to a floor plan?

Yes. Type "Add 4 duplex receptacles in each bedroom" and Aginera finds each bedroom from the room names on the drawing and places the receptacles as blocks on layer E-POWR-DEVC. The new work is shown in red with a count of what was drawn.

Can it add lighting and switches?

Yes. It draws ceiling, recessed, 2x4 troffer, wall and emergency lights, exit signs, single-pole, three-way and dimmer switches, and occupancy sensors. Light fixtures go on E-LITE-FIXT and switches on E-LITE-SWCH. It can also draw lighting circuits.

Can it draw a panel and home runs?

Yes. Ask for a panelboard by name, for example LP-1, and for home runs from the rooms. Panelboards go on E-POWR-PANL. It also draws conduit and cable tray, routed at right angles.

Does it do load or voltage-drop calculations?

No. It does no load, voltage-drop or code calculations. It drafts the layout you ask for, and a licensed professional must check it before anything is built.

I said "wall outlet" and "breaker panel". Is that a problem?

No. Everyday words work. A wall outlet is drawn as a duplex receptacle, a light switch as a single-pole switch, and a breaker panel as a panelboard.

Start with your floor plan

Upload a PDF floor plan here. It is converted to CAD and opens in the CAD viewer, where you type your first change under Edit by request. Asking and previewing are free with an Aginera account.

Have a DWG or DXF already? Upload the DWG or DXF.

CAD-exported PDFs (AutoCAD, Revit, MicroStation — real, selectable line-work) trace line for line into an editable DWG or DXF. Scans, photos and images (JPG, PNG) are traced from the pixels — clean, straight-on scans give the best CAD. If a scan is too rough to trace well, we tell you and hand the same file to Aginera's AI reader instead — a bill of materials from the sheet, or a 3D model for floor plans.

Live example — see a vector PDF traced into editable CAD, then try your own.

Editable CAD· DWG · our viewer, no Autodesk

Other free tools

Need quantities, not just a model?

The free tools run on a single drawing. Aginera's takeoff product reads a whole plan set and produces priced, sheet-referenced quantities.