HVAC · PDF, DWG or DXF in · DWG out

AI HVAC layout: diffusers, grilles and duct runs on a floor plan

Type what the plan needs and Aginera drafts it: supply diffusers, return and exhaust grilles, exhaust fans, equipment and duct runs, placed room by room as real CAD blocks on AIA/NCS mechanical layers. Upload a PDF, DWG or DXF and download the edited sheet as DWG or DXF.

Part of the Aginera AI MEP drafter.

What to type

Write the change the way you would say it to a drafter. Name the rooms as they are written on the drawing. Each request builds on the last.

  • “Put a supply diffuser in every office and run a supply duct from the AHU, 300x200”
  • “Add an exhaust fan in each toilet, tagged EF-1, EF-2, and a bill of materials”
  • “Add a return grille and a thermostat in each bedroom”
  • “Add a fan coil unit in each bedroom and run condensate pipe to the toilet”

HVAC symbols and layers

Symbols, placed as blocks

  • • Supply diffusers and linear slot diffusers
  • • Return and exhaust grilles
  • • Exhaust fans
  • • Thermostats
  • • VAV boxes
  • • Fan coil units
  • • Air handling units
  • • Fire and volume dampers

Runs, drawn at right angles

  • • Supply, return, exhaust and outside-air duct
  • • Chilled water pipe
  • • Refrigerant pipe
  • • Condensate pipe

Also on request: tags and numbering, notes, a bill of materials table and a symbol legend drawn on the sheet.

Symbol groupNCS layer
Supply diffusersM-HVAC-SDFF
Exhaust fansM-HVAC-EQPM
Supply ductM-DUCT-SUPP
Return ductM-DUCT-RETN

Layers follow the AIA/NCS (US National CAD Standard) naming. The bill of materials drawn on the sheet names the layer of each item.

What the result looks like

Residential first-floor plan converted from PDF to CAD, with receptacles, ceiling lights, switches, exhaust fans, a smoke detector and panelboard LP-1 drawn in red by typed request, and a bill of materials table listing each item with its NCS layer and quantity
A real first-floor plan after a few typed requests. The new work is in red: 8 duplex receptacles, 2 GFCI receptacles, 4 ceiling lights, 2 switches, 2 exhaust fans, 1 smoke detector and panelboard LP-1. The bill of materials on the right was drawn on the sheet and names the layer of each item.

What it does not do

Aginera drafts the change. A licensed professional must check the result before anything is built.

It does no load or code calculations, so it does not size duct. Say the size you want in the request, for example 300x200.

No calculations

It does no load, voltage-drop, hydraulic or code calculations. It places and draws what you ask for.

No dimensions, hatching, revision clouds or title-block edits

Add those in your CAD program after you download the DWG.

No Revit and no 3D

It works on 2D PDF, DWG and DXF drawings. It does not open or write Revit (RVT) files.

First drawing sheet of a multi-sheet PDF

On a PDF with several sheets it edits the first drawing sheet.

Rooms need a name on the drawing

Rooms are found from the room names written on the sheet. A room that is open to the next space, or has no name, may need the request re-worded.

Runs are not clash-checked

Duct, pipe and conduit runs are routed at right angles. They are not checked against structure or other services.

What it costs

Questions people ask

Can AI draw an HVAC duct layout on a floor plan?

Yes. Type "Put a supply diffuser in every office and run a supply duct from the AHU, 300x200". Aginera finds each office from the room names on the drawing, places the diffusers on layer M-HVAC-SDFF and draws the supply duct on M-DUCT-SUPP. Runs are routed at right angles.

Does it size the duct?

No. It does no load or code calculations. Say the size you want in the request, for example 300x200. A licensed professional must check the layout before anything is built.

Can it tag exhaust fans and list them?

Yes. Ask for "an exhaust fan in each toilet, tagged EF-1, EF-2, and a bill of materials". The fans are tagged in order and the bill of materials table is drawn on the sheet with each item, its layer and its quantity.

Which HVAC equipment and piping can it draw?

Thermostats, VAV boxes, fan coil units, air handling units, fire and volume dampers, and supply, return, exhaust and outside-air duct. It also draws chilled water, refrigerant and condensate pipe.

Are the duct runs clash-checked?

No. Runs are routed at right angles and are not checked against structure or other services. Check the routing in your CAD program.

Start with your floor plan

Upload a PDF floor plan here. It is converted to CAD and opens in the CAD viewer, where you type your first change under Edit by request. Asking and previewing are free with an Aginera account.

Have a DWG or DXF already? Upload the DWG or DXF.

CAD-exported PDFs (AutoCAD, Revit, MicroStation — real, selectable line-work) trace line for line into an editable DWG or DXF. Scans, photos and images (JPG, PNG) are traced from the pixels — clean, straight-on scans give the best CAD. If a scan is too rough to trace well, we tell you and hand the same file to Aginera's AI reader instead — a bill of materials from the sheet, or a 3D model for floor plans.

Live example — see a vector PDF traced into editable CAD, then try your own.

Editable CAD· DWG · our viewer, no Autodesk

Other free tools

Need quantities, not just a model?

The free tools run on a single drawing. Aginera's takeoff product reads a whole plan set and produces priced, sheet-referenced quantities.