PDF, DWG or DXF in · DWG out · AIA/NCS layers

AI MEP Drafter: add electrical, HVAC and plumbing to a DWG or PDF

The Aginera AI MEP drafter adds electrical, HVAC, plumbing and fire protection work to a floor plan from a request typed in plain words. Upload a PDF, DWG or DXF and you get the sheet back as a DWG or DXF, with every symbol placed as a real CAD block on its AIA/NCS layer and the duct, pipe and conduit runs drawn.

Updated November 2026 · Asking and previewing are free with an account · Also in Claude

Residential first-floor plan converted from PDF to CAD, with receptacles, ceiling lights, switches, exhaust fans, a smoke detector and panelboard LP-1 drawn in red by typed request, and a bill of materials table listing each item with its NCS layer and quantity
A real first-floor plan after a few typed requests. The new work is in red: 8 duplex receptacles, 2 GFCI receptacles, 4 ceiling lights, 2 switches, 2 exhaust fans, 1 smoke detector and panelboard LP-1. The bill of materials on the right was drawn on the sheet and names the layer of each item.

How it works

1.Upload the floor plan

Upload a PDF (vector or scanned), a DWG or a DXF. A PDF is first converted to CAD by the Aginera PDF to CAD converter, then opens in the CAD viewer.

2.Type the change

In the CAD viewer, open Edit by request and say what you want in plain words, for example "Add 4 duplex receptacles and a ceiling light with a switch in each bedroom".

3.Check the preview

Aginera finds each room from the room names on the drawing and shows the sheet with the new work in red, a count of what was drawn, what it assumed and what needs checking.

4.Ask again, then download

Each request builds on the last. When the sheet is right, download it as DWG (AutoCAD 2018) or DXF and finish it in your CAD program.

Aginera Edit by request dialog after the request 'Add 4 duplex receptacles and a ceiling light with a switch in each bedroom': the floor plan with the new symbols in red and the list 8 duplex receptacles on E-POWR-DEVC, 2 ceiling lights on E-LITE-FIXT, 2 switches on E-LITE-SWCH
One typed request: the new work comes back in red, with the count of each item and the layer it is on.
The whole sheet after a second request: exhaust fans EF-1 and EF-2, a smoke detector, panel LP-1 with a home run, and a bill of materials table drawn beside the plan, with the Edited DWG and DXF download buttons
A second request builds on the first. The bill of materials is drawn on the sheet, then you download the DWG or DXF.

Starting from a PDF? The conversion is done by the PDF to CAD converter. Then you add the MEP on top and take the result away as a DWG.

What you can ask for

It draws 54 symbols across 19 systems. Write the request the way you would say it to a drafter, and name the rooms as they are written on the drawing.

Electrical

  • “Add 4 duplex receptacles and a ceiling light with a switch in each bedroom”
  • “Put a GFCI receptacle in each toilet”
  • “Add panelboard LP-1 in the lobby and a home run from each bedroom”
  • “Add 2x4 troffers and an occupancy sensor in every office”

Symbols: duplex, gfci, quad and floor receptacles; switches: single-pole, three-way and dimmer; occupancy sensors; ceiling, recessed, 2x4 troffer, wall and emergency lights; exit signs; panelboards; junction boxes; disconnects and motor connections.

Runs: home runs; conduit; cable tray; lighting circuits.

AI electrical layout →

Mechanical (HVAC)

  • “Put a supply diffuser in every office and run a supply duct from the AHU, 300x200”
  • “Add an exhaust fan in each toilet, tagged EF-1, EF-2, and a bill of materials”
  • “Add a return grille and a thermostat in each bedroom”
  • “Add a fan coil unit in each bedroom and run condensate pipe to the toilet”

Symbols: supply diffusers and linear slot diffusers; return and exhaust grilles; exhaust fans; thermostats; vav boxes; fan coil units; air handling units; fire and volume dampers.

Runs: supply, return, exhaust and outside-air duct; chilled water pipe; refrigerant pipe; condensate pipe.

AI HVAC layout →

Plumbing

  • “Add a water closet and a lavatory in each toilet”
  • “Add a floor drain in each toilet and a cleanout in the service area”
  • “Add a water heater in the service area and run cold and hot water pipe to the kitchen”
  • “Add a kitchen sink in the kitchen and run a sanitary pipe to the toilet”

Symbols: lavatories and kitchen sinks; water closets and urinals; showers and bathtubs; drinking fountains; floor drains and cleanouts; hose bibbs; water heaters; shut-off valves and gas outlets.

Runs: cold and hot water pipe; sanitary pipe; vent pipe; storm pipe; gas pipe.

AI plumbing layout →

Fire and low voltage

  • “Add a smoke detector in every bedroom and in the lobby”
  • “Add sprinkler heads in each office”
  • “Add a data outlet in each bedroom and a wireless access point in the lobby”
  • “Add a pull station and a horn strobe in the lobby”

Symbols: smoke and heat detectors; pull stations and horn strobes; fire alarm panel; sprinkler heads; fire extinguishers; data and telephone outlets; wireless access points; cctv cameras and card readers.

Runs: sprinkler pipe.

Tags and numbering

Tag new work or number blocks already on the drawing: EF-1, EF-2 and so on.

“Number the exhaust fans EF-1, EF-2”

Bill of materials and legend

A bill of materials table and a symbol legend, drawn on the sheet. Notes too.

“Add a bill of materials and a symbol legend”

Cleanup of existing work

Erase a block or a layer, move work to another layer, rename a layer, or swap one block for another.

“Move the receptacles to layer E-POWR-DEVC”

Everyday words work

You do not need the drafting term. Say it the way the owner or the site crew would.

You typeAginera draws
wall outletduplex receptacle
light switchsingle-pole switch
breaker panelpanelboard
air ventsupply diffuser
air returnreturn grille
bathroom fanexhaust fan
toiletwater closet
bathroom sinklavatory
smoke alarmsmoke detector

AIA / NCS layers, real blocks

New work goes on layers named to the AIA/NCS standard (the US National CAD Standard). Each symbol is a block, not loose lines.

TradeSymbol groupNCS layer
ElectricalReceptaclesE-POWR-DEVC
ElectricalLight fixturesE-LITE-FIXT
ElectricalSwitchesE-LITE-SWCH
ElectricalPanelboardsE-POWR-PANL
Mechanical (HVAC)Supply diffusersM-HVAC-SDFF
Mechanical (HVAC)Exhaust fansM-HVAC-EQPM
Mechanical (HVAC)Supply ductM-DUCT-SUPP
Mechanical (HVAC)Return ductM-DUCT-RETN
PlumbingPlumbing fixturesP-FIXT
PlumbingCold water pipeP-DOMW-CPIP
PlumbingSanitary pipeP-SANR-PIPE
Fire and low voltageFire alarm devicesF-ALRM-DEVC
Fire and low voltageSprinkler headsF-SPRN-HEAD

We opened the edited DWG in Autodesk’s own viewer and translation service. Every symbol came through as a named block on its layer. The bill of materials drawn on the sheet names the layer of each item.

What it does not do

Aginera drafts the change. A licensed professional must check the result before anything is built.

No calculations

It does no load, voltage-drop, hydraulic or code calculations. It places and draws what you ask for.

No dimensions, hatching, revision clouds or title-block edits

Add those in your CAD program after you download the DWG.

No Revit and no 3D

It works on 2D PDF, DWG and DXF drawings. It does not open or write Revit (RVT) files.

First drawing sheet of a multi-sheet PDF

On a PDF with several sheets it edits the first drawing sheet.

Rooms need a name on the drawing

Rooms are found from the room names written on the sheet. A room that is open to the next space, or has no name, may need the request re-worded.

Runs are not clash-checked

Duct, pipe and conduit runs are routed at right angles. They are not checked against structure or other services.

What it costs

Use it from Claude

Edit by request is also available in Claude through the Aginera connector, and is coming to ChatGPT. Ask Claude for the change in the same plain words. Claude asks Aginera to draw it, shows you what changed, and can fetch the edited drawing file.

Tools: request_drawing_change, get_drawing_changes, get_changed_drawing_file.

Use Aginera in Claude →

Questions people ask

What is an AI MEP drafter?

It is a tool that drafts mechanical, electrical and plumbing work on a floor plan from a typed request. In Aginera you upload a PDF, DWG or DXF, type the change in plain words, and get the sheet back with the new symbols placed as real CAD blocks on AIA/NCS layers and the duct, pipe or conduit runs drawn. You download the result as DWG or DXF.

Can AI add electrical outlets to a floor plan?

Yes. Type a request such as "Add 4 duplex receptacles and a ceiling light with a switch in each bedroom". Aginera finds each bedroom from the room names written on the drawing, places the receptacles, lights and switches as blocks, and shows the new work in red with a count of what was drawn, what it assumed and what needs checking.

Can I edit a DWG without AutoCAD?

Yes. Upload the DWG or DXF to Aginera, open Edit by request in the CAD viewer and type the change. You see the result in the browser. The edited file downloads as DWG (AutoCAD 2018) or DXF, so you or your drafter can open it in a CAD program later to finish it.

Does it work on a PDF?

Yes, vector or scanned. A PDF floor plan is first converted to CAD by the Aginera PDF to CAD converter, then you edit it by request like any other drawing. On a PDF with several sheets it edits the first drawing sheet.

Which CAD layers does it use?

AIA/NCS layers, the US National CAD Standard. Examples: E-POWR-DEVC, E-LITE-FIXT, E-LITE-SWCH, E-POWR-PANL, M-HVAC-SDFF, M-HVAC-EQPM, M-DUCT-SUPP, M-DUCT-RETN, P-FIXT, P-DOMW-CPIP, P-SANR-PIPE, F-ALRM-DEVC, F-SPRN-HEAD. The bill of materials it draws on the sheet names the layer of each item.

Does it do load calculations?

No. It does no load, voltage-drop, hydraulic or code calculations. It drafts the change you ask for. A licensed professional must check the result before anything is built.

Is the output a real DWG?

Yes. The file is a DWG in AutoCAD 2018 format, or a DXF. Symbols are real blocks on their layers, not exploded lines or a picture. We opened the edited DWG in Autodesk’s own viewer and translation service, and every symbol came through as a named block on its layer.

Does it work with Revit?

No. It does not open or write Revit (RVT) files, and it does not work in 3D. It edits 2D drawings: PDF, DWG and DXF.

What does it cost?

Asking and previewing are free with an Aginera account. Free accounts get a limited number of requests a day. The edited DWG or DXF comes with that drawing’s one-time CAD purchase, the same purchase as its converted CAD file. One purchase covers the drawing and every edit of it. No subscription is required.

Can I use it from Claude or ChatGPT?

It is available in Claude through the Aginera connector, and is coming to ChatGPT. In Claude the tools are request_drawing_change, get_drawing_changes and get_changed_drawing_file.

Try it on your own floor plan

Upload a PDF floor plan here. It is converted to CAD and opens in the CAD viewer, where you type your first change under Edit by request. Asking and previewing are free with an Aginera account.

Have a DWG or DXF already? Upload the DWG or DXF.

CAD-exported PDFs (AutoCAD, Revit, MicroStation — real, selectable line-work) trace line for line into an editable DWG or DXF. Scans, photos and images (JPG, PNG) are traced from the pixels — clean, straight-on scans give the best CAD. If a scan is too rough to trace well, we tell you and hand the same file to Aginera's AI reader instead — a bill of materials from the sheet, or a 3D model for floor plans.

Live example — see a vector PDF traced into editable CAD, then try your own.

Editable CAD· DWG · our viewer, no Autodesk
Need quantities from the same drawings? Aginera also runs a quantity takeoff of MEP plan sets.

Other free tools

Need quantities, not just a model?

The free tools run on a single drawing. Aginera's takeoff product reads a whole plan set and produces priced, sheet-referenced quantities.